Product Cold Filter Plugging Point Process Analyzer

Cold Filter Plugging Point Process Analyzer

CFPP-4
-

Benefits

  • The only ASTM compliant CFPP process analyzer
  • Identical test mesh filter as used in the laboratory
  • Stepped and linear cooling
  • Network and fieldbus communication
Get a Quote

Marking

ATEX: II 2G Ex h IIC T4 Gb X
IECEx: Ex IIC T4 Gb
NEC 500: Class I, Division 2, Group B,C and D
NEC 505: Class I, Zone 1, AEx db eb ib pxb IIC
T3 resp. T4
CEC Sec. 18: Ex db eb ib pxb IIC T3 resp. T4
TR CU: II Gb T4 X

Ambient Temperature

T4

Description

To remain competitive, today’s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties in the process directly.
The cold filter plugging point (CFPP) is the lowest temperature at which diesel and domestic heating fuels will pass through a filter in a given time when cooled under certain conditions. CFPP is supposed to give an estimate for the lowest temperature at which these fuels will flow in fuel systems without problems. This temperature is important especially in cold temperature regions where high CFPP of diesel fuel could result in clogging up vehicles’ fuel systems.

Technical Data

Technology discontiniously mearement of CFPP with linear cooling bath
Method compliant with: ASTM D 6371 DIN EN 116 DIN EN 16329 (linear cooling bath) IP 309
Sample at inlet filtered 50 μm, no suspended water ( 500 ppm), bubble-free
10 to 40 l/h
1 to 4 bar (14.5 to 58 psi)
max. 40 °C, max. 37 cSt at inlet temperatur
Sample at outlet atmospheric pressure
Electrical data max. 8 outputs (4 to 20 mA; 1000 Ω), active isolated on request
4 to 20 mA; 160 Ω
DC 24 V; max. 0.5 A; sum alarm Ready/Come-Read, Power identification
high: DC 15 to 28 V; low: DC 0 to 4 V
Communication MODBUS RTU/TCP (RS485, RS422, VDSL/FO (IS)
MODBUS/TCP via FOC is
remote software with modem, ISDN, Ethernet via VDSL modem FO (FS)
Ambient conditions operation 5 to 35 °C (41 to 95 °F) storage -20 to 60 °C (-4 to 140 °F)
operation 5 to 80 % relative humidity, non-corrosive; storage 5 to 80 % relative humidity, non-corrosive
IP 54 (comparable with NEMA 13)
HMI touch display 19"
remote access on request
cyber security
operating system Windows10 enterprise LTSB
Bartec Benke control software PACS
Process connections tube fittings: typically Swagelok 6mm/12mm/18mm; others on request
sample inlet for 1 sample stream and 1 validation stream
sample outlet
vent line (if required)
coolant (if required)
Weight and dimensions approx. 400 kg
(W x H x D) approx. 1140 x 2130 x 710 mm
free space right: 150 mm/left: 100 mm

Application Notes

  • BENKE CFPP-4 Understanding the challenges of the measurement of the Cold Filter Plugging Point

      Application Note

    • EN

Questionnaires/Requirement Sheets

  • Questionnaire_PL AMS_PAT

Data Sheets

  • BENKE Cold Filter Plugging Point Process Analyzer CFPP-4

Brochures

  • BENKE Cold Filter Plugging Point Process Analyzer CFPP-4

  • Cyber Security Solutions for BARTEC BENKE analyzers