Pressure Monitor Module
outlet device for Ex pxb or Ex pyb protected equipment in zone 1/21
17-51P3-1.03
Benefits
- Compact design
- Integrated flying spark barrier
- Easy handling
Marking
Ambient Temperature
Operating temperature-20 °C to +80 °C
(-4 °F to 176 °F)
Storage temperature
-20 °C to +80 °C
(-4 °F to 176 °F)
Description
The pressure switch module is a component of pressurized controls for zone 1/21.
For zone 1/21 applications, variants with different orifice sizes are available and can thus be optimally selected for the protected Ex p volume.
The function of the pressure monitor module is on the one hand to measure the flow in connection with the Ex p control unit and on the other hand it serves as a pressure safety valve.
Technical Data
Protection class | IP 65 |
---|---|
Flying spark barrier | 3-fold |
Structure | with Ex px/py operating equipment Mounting position: - any position - plastic body inside Ex p operating equipment |
Opening pressure | 3 mbar |
Installation | Mounting hole: Ø 37 mm |
Connection | Quick plug-in connector for hose |
Measuring orifice | 8 mm up to 18 mm |
Ex p Control Unit | APEXpx or APEXpy |