Ambient Temperature
-25 °C up to +100 °CDescription
Industrial processes often take place within closed containers, under increased pressure or even vacuum conditions. It is therefore of utmost importance that no media leakages or pressure/vacuum drops occur when cables are led in. Our BARTEC pressure and vacuum sealed cable entries provide a simple and cost-effective solution to this problem. The cable entries essentially consist of a metal sleeve encapsulating the whole length of the electric conductors within epoxy-resin. This means that sealing is not only guaranteed for the whole length of the conductors but also through the stranded conductors themselves. Depending on their field of application, BARTEC pressure and vacuum sealed cable entries can be used at temperatures of -70 °C to +150 °C. With regard to the actual temperature and surrounding media, pressures of 10-6 mbar to 200 bar can be withstood.
Technical Data
Protection class | IP 68 |
---|---|
Dimensions | see data sheet |
Pressure | 63 bar to RT (RT= +25 °C) |
Voltage | see data sheet |
Connection | Cable lengths: 500 mm Core lengths: 2.5 m (other lengths on request) Nominal conductor cross section: 0.35 mm² to 6 mm² |