Product Cold applied kit CAK

Cold applied kit CAK

Connection technology and termination for self-regulating heating cable
27-59CX-........

Benefits

  • Easy installation with silicone adhesive
  • Space-saving solution
  • Under insulation applicable
Get a Quote

Marking

ATEX:
II 2G Ex eb 60079-30-1
II 2D Ex tb 60079-30-1

IECEx:
Ex eb 60079-30-1
Ex tb 60079-30-1

Ambient Temperature

Max. withstand temperature / max. Service temperature end seal +200°C

Certification

  • System Certificate ATEX
  • System Certificate IECEx

Description

The cold applied technology is the ideal solution when connecting the PSB, MSB, HSB, HSB+ and HTSB heating cable to the junction box.

The end termination is achieved using a space-saving silicone end cap. The use of silicone parts and silicone adhesive enables the heating cable to be installed easily and quickly. In addition, no fire certificate is needed for installation in a potentially explosive atmosphere.

Technical Data

Ambient temperature -55°C to +55°C
-67°F to +131°F
Max. withstand
temperature / max.
Service temperature end seal
+200 °C
+392°F
Min. installation temperature -60 °C
-76°F
Material Silicone, brass, stainless steel, brass nickel plated
Ingress Protection IP66

Data Sheets

  • Data Sheet CAK-SRS/SRG - ATEX/IECEx