Universal supply module
Benefits
- Enables connection of scanner to non-Ex systems
- Variety of serial interfaces and connecting cables supported
- Max. cable length 1.200 m
Marking
ATEX:
BCS3608ex-NI
Ex II 3G Ex ec [ic] IIC T4 Gc
Ex II 3G Ex tc [ic] IIIC T80°C Dc IP 64
BCS3678ex-NI
Ex II 3G Ex ec IIC T4 Gc
Ex II 3D Ex tc IIIC T80°C Dc IP 64
IECEx:
BCS3608ex-NI:
Ex ec [ic] IIC T4 Gc
Ex tc [ic] IIIC T80°C Dc IP 64
BCS3678ex-NI:
Ex ec IIC T4 Gc
Ex tc IIIC T80°C Dc IP 64
Ambient Temperature
Operating temperature-20°C to +50°C (-4°F to 122°F)
Storage temperature
-40°C to +70°C (-40°F to 148°F)
Description
The supply modules are used for an intrinsically safe supply (barrier) of the hand-held scanners and contain a safety barrier (evaluation barrier) for the data lines in a potentially explosive atmosphere.
The data lines can be connected from the hazardous area to non-Ex systems, e.g. PCs or PLCs, without an additional barrier/safety barrier.
The data interface to be used can be set with a barcode. These adjustment possibilities make it easier for an existing old system to subsequently be converted and modified.
Technical Data
Dimensions | 81 mm x 222 mm x 88 mm (3.2 inch x 8.7 inch x 3.5 inch) |
---|---|
Weight | approx. 1070 g (approx. 2.36 lb) |
IP Rating (IEC 60529) | IP 65 |
Connection | One hand-held scanner can be connected to the Universal supply module. |
Accessories/System Overview
Configurator
Do you want to load external content to display a product configurator (check consent banner)?