MPCnet Ex temperature limiter
17-8851-00300000
Benefits
- ATEX approval
- Optimised for trace heating applications (with service entry)
- Fault monitoring
- In conjunction with Pt100 Ex, it can be used for monitoring temperature in explosionprotected heating circuits
Marking
Ex II (2)G [Ex e]
Ambient Temperature
-20 °C to +40 °CCertification
-
EU Type Examination Certificate
Description
The TL Ex safety temperature limiter is a constituent part of the MPCnet system and is used to monitor heatings and heating circuits. The device is for installation in non-hazardous areas. The heatings or heating circuits can be installed both in media-protected and also in hazardous (potentially explosive) areas
Technical Data
Mechanical data | Dimensions 22.5 mm x 100 mm x 114.5 mm |
---|---|
Installation: mounting rail TH35 metal | |
Protection class IP 20 | |
Electrical | measuring range -50 °C to +600 °C |
Measurement range accuracy +/-1°C | |
Voltage DC 24 V Input current 105 mA, maximum 2,7 W |