Conduit fittings and drain/breather valves
Flameproof fittings for Zone 1/2 - 21/22
PLG... - NP... - EM... - EL... - DL... - DB... - ECD
Benefits
- Immediate mechanical connection between devices, conduit pipes, enclosures, apparatus, and so on.
- Conduit fittings are used in rigid/IMC conduit systems to connect different sizes of conduit together or enclosures and apparatus between them.
Marking
ATEX:
(Ex II 2 G) Ex db IIC Gb
(Ex II 2 G) Ex eb IIC Gb
(Ex II 2 D) Ex tb IIIC Db IP66
IECEx:
Ex db IIC Gb
Ex eb IIC Gb
Ex tb IIIC Db IP66
Ambient Temperature
-60 °C to +130 °C (standard)Description
Flameproof Ex d conduit fittings BARTEC are designed to be installed in industrial plants, where potential hazardous atmos-pheres occur.
These areas are either classified as zone 1 and 2 or as zone 21 and 22.
Made in different materials to satisfy any type of application in environments with the presence of aggressive corrosion agents.
Technical Data
Protection class | IP 66 or IP 68 (IEC/EN 60529) |
---|---|
Material | Aluminium alloy Galvanized steel Nickel plated brass Stainless steel |
Weight | see data sheet |
Dimensions | see data sheet |
Manuals/Operating Instructions/Guides
-
ATEX - Instruction for use - Drain/Breather valve
-
ATEX - Instruction for use - Conduit fittings
-
IECEx - Instruction for use - Drain/Breather valve
-
IECEx - Instruction for use - Conduit fittings
-
INMETRO - Instruction for use - Drain/Breatheer valve
-
INMETRO - Instruction for use - Conduit fittings
-
NEC505 - Instruction for use - Drain/Breather valve
-
NEC505 - Instruction for use - Conduit fittings
Declarations
Data Sheets
-
Data sheet - Conduit fittings, locknuts, bushings, drain/breather valves