Marking
ATEX:
II 2G Ex db eb op is ia/ib [ib] IIC T6...T4 Gb
II 2(1)G Ex db eb op is ia/ib [ia Ga] IIC T6...T4 Gb
II 2D Ex tb op is ia/ib [ib] IIIC T80°C, T95°C, T130°C Db
II 2(1)D Ex tb op is ia/ib [ia Da] IIIC T80°C, T95°C, T130°C Db
IECEx:
Ex db eb op is ia/ib [ib] IIC T6...T4 Gb
Ex db eb op is ia/ib [ia Ga] IIC T6...T4 Gb
Ex tb op is ia/ib [ib] IIIC T80°C, T95°C, T130°C Db
Ex tb op is ia/ib [ia Da] IIIC T80°C, T95°C, T130°C Db
Ambient Temperature
-20 °C ≤ Ta ≤ +70 °C(-4 °F ≤ Ta ≤ +158 °F)
Description
BARTEC offers two type series of explosion proof encapsulated enclosures for using electric components in hazardous (potentially explosive areas).
Within the scope of the EC model test certification, these can be fitted with industrial standard units, such as e.g. small-type motors, printed circuit boards and cameras. The mounted parts are evaluated by BARTEC, fitted into a suitable housing and provided as a complete device with the corresponding ATEX marking.
This housing series offers optimum solution approaches for control, regulating and display devices in Zone 1 and zone 21 hazardous areas.
Technical Data
Protection class | min. IP 54/IEC 60529 |
Material | Metall, surface bare, electro-plated or varnished |