| Mechanical Data | Protection class according to EN 60529: Cover gasket IP 65 Cable gland for power supply cables IP 67 |
|
|---|---|---|
| Material polyester, glass-fibre reinforced | ||
| Dimensions 110 x 75 x 55 mm | ||
| Impact resistance 7 Nm | ||
| Connection | Supply cable, cross section 2.5 mm² | |
| Voltage max. AC 60 V | ||
Ex II 2G Ex eb IIC T6 or T5 Gb
Ex II 2D Ex tb IIIC T80 °C, T95 °C Db
Ex II 2G Ex ia IIC T6 or T5 Gb
Ex II 2D Ex tb IIIC T80 °C, T95 °C Db
Ambient temperature:
-55 °C to +40 °C (T6)
-55 °C to +55 °C (T5 ,T4)
The junction boxes for Pt100 Ex allow one or more two-wire or three wire Pt100 resistance thermometers to be connected to a signal line.
The enclosures have the appropriate terminals and the required cable glands.