| Dimensions | see data sheet |
|---|---|
| Intrinsically safe parameters |
Only for connection to circuits in type of protection Intrinsic Safety Ex ia IICMaximum values per circuit:Max. input voltage (Ui): 30 V DC Max. input current (Ii): 1 A DC Internal inductance (Li): Negligibly low Internal capacitance (Ci): Negligibly low |
| Pressure on the non Ex d side |
≤ 6 bar (87 psi) |
| Rated cross-section | 0.75 mm² |
| Material | Threaded sleeve: Brass nickel plated Electrode: Brass O-ring: EPDM, NBR, FKM |
| Degree of protection | IP66 |
ATEX:
Ex II 2G Ex db ia IIC Gb
Ex I M2 Ex db ia I Mb
IECEx:
Ex db ia IIC Gb
Ex db ia I Mb
Service temperature (Ts):
-60 °C to +110 °C
(-76 °F to +230 °F)
depending on the core wire used
The electrode line bushing Ex + pressure-tight type 37-94, serves to detect leakage in a shaft seal. An appropriate evaluating processor unit can indicate to the user in good time when there is a leak or when maintenance is due.
The electrode line bushing can also guide signals safely through walls of flameproof encapsulated operating equipment in potentially explosive areas. The electrode consists of a threaded metal sleeve and a metal electrode one block by means of a creepage-proof insulation material. Whether the core wire and the electrode are led out of the boss side or the sleeve side is optional.