Electrode Line Bushing Ex + Pressure-Tight

for use in Zone 1
37-94
Benefits

– Explosion-proof & pressure-sealed
– Durable & robust construction
– Versatile applications

Get a Quote
Dimensions see data sheet
Intrinsically safe
parameters
Only for connection to circuits in type of
protection Intrinsic Safety Ex ia IICMaximum values per circuit:Max. input voltage (Ui):   30 V DC
Max. input current (Ii):   1 A DC
Internal inductance (Li):  Negligibly low
Internal capacitance (Ci):  Negligibly low
Pressure on the
non Ex d side
≤ 6 bar (87 psi)
Rated cross-section 0.75 mm²
Material Threaded sleeve: Brass nickel plated
Electrode: Brass
O-ring: EPDM, NBR, FKM
Degree of protection IP66

ATEX:
Ex II 2G Ex db ia IIC Gb
Ex I M2 Ex db ia I Mb

IECEx:
Ex db ia IIC Gb
Ex db ia I Mb

Service temperature (Ts):
-60 °C to +110 °C
(-76 °F to +230 °F)
depending on the core wire used

Description

The electrode line bushing Ex + pressure-tight type 37-94, serves to detect leakage in a shaft seal. An appropriate evaluating processor unit can indicate to the user in good time when there is a leak or when maintenance is due.

The electrode line bushing can also guide signals safely through walls of flameproof encapsulated operating equipment in potentially explosive areas. The electrode consists of a threaded metal sleeve and a metal electrode one block by means of a creepage-proof insulation material. Whether the core wire and the electrode are led out of the boss side or the sleeve side is optional.