| Protection class | Up to IP67 acc. to EN 60529 and NEMA 4X acc. to UL 50E. Requires correct installation in in a mounting hole on an enclosure with appropriate degree of protection. |
|---|---|
| Mounting | – Installation in enclosures with a wall thickness of 1mm to 6 mm (0.04 in to 0.24 in) – Suitable for through-holes 30.3 mm (1.19 in) – Torque fixing nut 2.8 to 3.4 Nm |
| Service temperature | -55 °C to +70 °C (-67 °F to +158 °F) (related to explosion protection acc. to EN IEC 60079-0) |
| Weight | see data sheet |
Service temperature (Ts):
-55 °C to +70 °C
(-67 °F to +158 °F)
ATEX/UKEX:
Ex II 2G Ex eb IIC Gb
Ex II 2D Ex tb IIIC Db
IECEx:
Ex eb IIC Gb
Ex tb IIIC D
CEC (UL Mark):
Ex eb IIC Gb
Ex tb IIIC Db
Class I, Division 2, Groups A, B, C, D
Class II, Division 2, Groups F, G
Class III, Division 2
NEC (UL Mark):
Class I, Zone 1, AEx eb IIC Gb
Zone 21, AEx tb IIIC Db
Class I, Division 2, Groups A, B, C, D
Class II, Division 2, Groups F, G
Class III, Division 2
A large number of variants and versions of control and signal device actuator are available for the ComEx control and indicator units.
All control and signal device actuator are made of high-quality thermoplastic and can be used in almost all potentially explosive areas.
The Control and signal design devices enables easy and safe mounting and can be complemented by useful accessories.
The components are developed and certified for global hazardous areas.